The technical specifications of the Cisco 1701 ADSL security access router are as follows:

Feature

Specifications

Physical interfaces/ports

One ADSLoPOTS WAN port:

  • Complies with ANSI T1.413 issue 2 and ITU 992.1 (G.DMT).
  • Supports ATM adaptation layer 5 (AAL5) services and applications.
  • Interoperates with the following DSLAMs: Cisco (6130 and 6260), Alcatel (ASAM 1000 and 7300), Lucent Stinger (24 and 48-port Linecards), ECI HiFOCuS (ADI 918 and 930)

One ISDN BRI WAN port:

  • ISDN dialup and ISDN DSL (IDSL) at 64 and 128 Kbps.
  • Encapsulation over IDSL, Frame Relay, and Point-to-Point Protocol (PPP).
  • ISDN WAN port features are consistent with the Cisco 1-port ISDN WAN interface card (WIC-1B-S/T).

One 10/100BASE-TX Fast Ethernet port (RJ-45):

  • Automatic speed detection.
  • Automatic duplex negotiation.
  • IEEE 802.1Q VLAN routing.

One auxiliary (AUX) port:

  • RJ-45 jack with EIA/TIA-232 interface.
  • Asynchronous serial data rates up to 115.2 Kbps.

One console port:

  • RJ-45 jack with EIA/TIA-232 interface.
  • Transmit/receive rates up to 115.2 Kbps (default 9600 bps, not a network data port).

Memory

  • Default DRAM memory: 64 MB
  • Maximum DRAM memory: 128 MB
  • Default Flash memory: 32 MB
  • Maximum Flash memory: 32 MB

Dimensions and weight

  • Width: 11.2 in.(28.4 cm)
  • Height: 3.1 in. (7.85 cm)
  • Depth: 8.7 in. (22.1 cm)
  • Weight: 2.9 lb (1.32 kg)

Power

  • AC input voltage: 100 to 240 VAC
  • Frequency: 47 to 64 Hz
  • AC input current: 0.5 amps
  • Power dissipation: 20W (maximum)

Environmental

  • Operating temperature: 32 to 104 F (0 to 40 C)
  • Nonoperating temperature: -4 to 149 F (-20 to 65 C)
  • Relative humidity: 10 to 85 percent noncondensing, operating; 5 to 95 percent noncondensing, nonoperating

Safety certifications

  • UL 1950
  • CSA 22.2—No. 950
  • EN60950
  • EN41003
  • AUSTEL TS001
  • AS/NZS 3260
  • ETSI 300-047
  • BS 6301 (power supply)

EMI classifications

  • AS/NRZ 3548 Class A
  • Class B
  • FCC Part 15 Class B
  • EN60555-2 Class B
  • EN55022 Class B
  • VCCI Class II
  • CISPR-22 Class B

Immunity standards

  • 55082-1 Generic Immunity Specification Part 1: Residential and Light Industry
  • IEC 1000-4-2 (EN61000-4-2)
  • IEC 1000-4-3 (ENV50140)
  • IEC 1000-4-4 (EN61000-4-4)
  • IEC 1000-4-5 (EN61000-4-5)
  • IEC 1000-4-6 (ENV50141)
  • IEC 1000-4-11
  • IEC 1000-3-2

Artboard 1 copy 2 Need more help?


 